Difference between revisions of "OCP4-IPI-libvirt"
(→Virtual Machine Configuration: small bits) |
(→Virtual Machine Configuration: added vbmc notes) |
||
Line 335: | Line 335: | ||
When configuring other nodes, simply remember to change the node name, disk image name, and MAC addresses to be unique. Adjust hardware resources accordingly for compute nodes. | When configuring other nodes, simply remember to change the node name, disk image name, and MAC addresses to be unique. Adjust hardware resources accordingly for compute nodes. | ||
+ | |||
+ | What is important for OCP IPI to be able to perform the installation properly is to register each virtual machine with <code>vbmcd</code> and assign it with a port. | ||
+ | |||
+ | <pre> | ||
+ | $ vbmc add --port=6211 controlplane1 | ||
+ | $ vbmc list | ||
+ | +-------------------+---------+---------+------+ | ||
+ | | Domain name | Status | Address | Port | | ||
+ | +-------------------+---------+---------+------+ | ||
+ | | controlplane1 | down | :: | 6211 | | ||
+ | +-------------------+---------+---------+------+ | ||
+ | $ vbmc start controlplane1 | ||
+ | $ vbmc list | ||
+ | +-------------------+---------+---------+------+ | ||
+ | | Domain name | Status | Address | Port | | ||
+ | +-------------------+---------+---------+------+ | ||
+ | | controlplane1 | running | :: | 6211 | | ||
+ | +-------------------+---------+---------+------+ | ||
+ | $ sudo ss -aunp | grep 6211 | ||
+ | UNCONN 0 0 *:6211 *:* users:(("vbmcd",pid=766290,fd=21)) | ||
+ | </pre> | ||
+ | |||
+ | There is no need to run the <code>vbmc</code> client as root as it is the daemon that is running as root and can see all the VMs accessible through the <code>qemu:///system</code> URL. | ||
+ | |||
+ | Of course there are options. For any VM you add, you can specify a custom libvirt URL and credentials if necessary (options <code>--libvirt-uri</code>, <code>--libvirt-sasl-username</code>, and <code>--libvirt-sasl-password</code>), a custom set of IPMI admin credentials (options <code>--username</code> and <code>--password</code>, they default to <code>admin</code> and <code>password</code>), and a custom IP address to listen on (defaults to all addresses, use option <code>--address</code> to restrict it). | ||
+ | |||
+ | <pre> | ||
+ | $ vbmc show controlplane1 | ||
+ | +-----------------------+-------------------+ | ||
+ | | Property | Value | | ||
+ | +-----------------------+-------------------+ | ||
+ | | active | True | | ||
+ | | address | :: | | ||
+ | | domain_name | controlplane1 | | ||
+ | | libvirt_sasl_password | *** | | ||
+ | | libvirt_sasl_username | None | | ||
+ | | libvirt_uri | qemu:///system | | ||
+ | | password | *** | | ||
+ | | port | 6211 | | ||
+ | | status | running | | ||
+ | | username | admin | | ||
+ | +-----------------------+-------------------+ | ||
+ | </pre> | ||
+ | |||
+ | Once started (which just opens the port) you can test the BMC connection using <code>ipmitool</code> or similar. | ||
+ | |||
+ | <pre> | ||
+ | $ ipmitool -I lanplus -H localhost -p 6211 -U admin -P password chassis status | ||
+ | System Power : off | ||
+ | Power Overload : false | ||
+ | Power Interlock : inactive | ||
+ | Main Power Fault : false | ||
+ | Power Control Fault : false | ||
+ | Power Restore Policy : always-off | ||
+ | Last Power Event : | ||
+ | Chassis Intrusion : inactive | ||
+ | Front-Panel Lockout : inactive | ||
+ | Drive Fault : false | ||
+ | Cooling/Fan Fault : false | ||
+ | </pre> | ||
+ | |||
+ | That's it! We're ready to install OCP! | ||
== Installer Configuration == | == Installer Configuration == |
Revision as of 13:28, 25 January 2024
Introduction
What I Assume
- You know how OpenShift installation works and what the difference between IPI and UPI is.
- You know about the OpenShift Machine API and various underlying mechanisms.
- You understand the different types of network interfaces on Linux and different
libvirt
networks. - You are familiar and comfortable with NetworkManager and the
nmcli
tool. - You are familiar and comfortable with
libvirt
CLI and XML. - You are familiar and comfortable with
qemu-img
tool. - We are not talking about any firewall restrictions here - it is your responsibility to ensure traffic is not blocked.
Outcomes
The installation described is for a fully managed IPI running OpenShift Container Platform v4.14, initially with three master and two worker nodes.
At a later point, I will add a couple of steps needed to grow the cluster by one extra worker node.
OpenShift Container Platform IPI Installation Using Libvirt
Prerequisites
Hardware requirements for the cluster:
- 136 GiB RAM (32 GiB per control plane, 20 GiB per compute node), max overcommit ratio of 1.5 (make sure enough swap is available)
- 52 vCPUs (12 per control plane, 8 per compute node), max overcommit ratio of 1.3 (higher might work, but will slow down the installation horribly and may ultimately fail)
- one physical network interface that will be used for the public bridged network
- a physical or virtual network interface that will be used for the provisioning network bridge
Hardware requirements for the installation client (provisioner) machine:
- a minimum of 8 GiB RAM and 4 CPUs
- a network connection to both the public bridged network and the provisioning network
Due to the fact provisioner needs access to both networks, and the provisioning network in this guide is a virtual one, it might be best if you define the provisioner as a VM, with the same network interface settings as the control/compute nodes.
In the case you want to run the workloads spread across several hypervisor hosts, there are some extra steps, but nothing big. More on that in #Installation Spanning Multiple Hypervisors below.
Software artifacts needed on the provisioner host:
-
oc
, the command line client, of the corresponding version - download from https://mirror.openshift.com/pub/openshift-v4/clients/ocp/ -
libvirt-client
package is required foropenshift-baremetal-install
to be able to communicate to hypervisor(s) -
ipmitool
or some other IPMI client - a
pull-secret
file containing authentication credentials for OpenShift Container Platform registries - download from https://console.redhat.com/openshift/ - an SSH keypair that can be used for accessing OpenShift nodes
Host Configuration
Beyond the logical requirement of having libvirt
installed and started, here are the other configuration details for the hypervisor.
Network Settings
First thing you definitely need to make sure of, is that IP forwarding is enabled.
$ sysctl net.ipv4.ip_forward 1
Linux network settings need to be configured to have two Linux bridges, a public and a private provisioning one.
- public bridge, call it
bridge0
, needs to have the public network interface enslaved to it - private bridge, call it
provbr0
, can be a virtual bridge since it is only needed for the provisioning network, which is supposed to be isolated and without any infrastructure services (such as DHCP, DNS, etc.)
It would be wonderful if the bridges could be OpenVSwitch ones, but unfortunately the Terraform bundled with openshift-baremetal-install
currently does not include an OpenVSwitch provider, so there's goodbye to that.
As an example, here is my host configuration.
Public bridge:
$ ip addr show bridge0 6: bridge0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default qlen 1000 link/ether 48:21:0b:57:0e:06 brd ff:ff:ff:ff:ff:ff inet 172.25.35.2/24 brd 172.25.35.255 scope global noprefixroute bridge0 valid_lft forever preferred_lft forever inet6 fe80::4a21:bff:fe57:e06/64 scope link valid_lft forever preferred_lft forever $ ip addr show enp86s0 2: enp86s0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq master bridge0 state UP group default qlen 1000 link/ether 48:21:0b:57:0e:06 brd ff:ff:ff:ff:ff:ff $ bridge link | grep "master bridge0" 2: enp86s0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 master bridge0 state forwarding priority 32 cost 100
Provisioning bridge:
$ ip addr show provbr0 5: provbr0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default qlen 1000 link/ether ce:70:26:9c:88:a4 brd ff:ff:ff:ff:ff:ff inet 10.1.1.2/24 brd 10.1.1.255 scope global noprefixroute provbr0 valid_lft forever preferred_lft forever inet6 fe80::cc70:26ff:fe9c:88a4/64 scope link valid_lft forever preferred_lft forever $ bridge link | grep "master provbr0"
Installation Spanning Multiple Hypervisors
If you want to have your cluster spanning multiple hypervisors, make sure there is also a VXLAN connection between all the provisioning bridges.
You can do that by creating a vxlan
type interface, which is a slave connection of type bridge
, and the master is set to provbr0
. Choose any unique VXLAN ID, and make sure it is the same on all interconnected hosts.
As an example, here is one VXLAN interface connecting hypervisor A to B.
$ nmcli con show provbr0-vxlan10 | grep -E '^(connection|vxlan)' | grep -vE '(default|uuid|--|-1|unknown)' connection.id: provbr0-vxlan10 connection.type: vxlan connection.interface-name: provbr0-vxlan10 connection.autoconnect: yes connection.autoconnect-priority: 0 connection.timestamp: 1703164860 connection.read-only: no connection.master: provbr0 connection.slave-type: bridge connection.gateway-ping-timeout: 0 vxlan.id: 10 vxlan.local: 172.25.35.2 vxlan.remote: 172.25.35.3 vxlan.source-port-min: 0 vxlan.source-port-max: 0 vxlan.destination-port: 4790 vxlan.tos: 0 vxlan.ttl: 0 vxlan.ageing: 300 vxlan.limit: 0 vxlan.learning: yes vxlan.proxy: no vxlan.rsc: no vxlan.l2-miss: no vxlan.l3-miss: no
And this is the corresponding VXLAN interface definition connecting host B to A.
$ nmcli con show provbr0-vxlan10 | grep -E '^(connection|vxlan)' | grep -vE '(default|uuid|--|-1|unknown)' connection.id: provbr0-vxlan10 connection.type: vxlan connection.interface-name: provbr0-vxlan10 connection.autoconnect: yes connection.autoconnect-priority: 0 connection.timestamp: 1697549049 connection.read-only: no connection.master: provbr0 connection.slave-type: bridge connection.gateway-ping-timeout: 0 vxlan.id: 10 vxlan.local: 172.25.35.3 vxlan.remote: 172.25.35.2 vxlan.source-port-min: 0 vxlan.source-port-max: 0 vxlan.destination-port: 4790 vxlan.tos: 0 vxlan.ttl: 0 vxlan.ageing: 300 vxlan.limit: 0 vxlan.learning: yes vxlan.proxy: no vxlan.rsc: no vxlan.l2-miss: no vxlan.l3-miss: no
In this case, bridge link
will of course initially also show the provbr0-vxlan10
interface as a slave, and will not show empty as above.
$ bridge link | grep "master provbr0" 7: provbr0-vxlan10: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 master provbr0 state forwarding priority 32 cost 100
libvirt
Settings
Your libvirt
will of course need to know about those network bridges in order to be able to attach VMs to them.
For that, you will need two network definitions, looking a bit like the following XML. Make sure they are autostart for least headache.
$ sudo virsh net-dumpxml external <network> <name>external</name> <uuid>whatever</uuid> <forward mode='bridge'/> <bridge name='bridge0'/> </network> $ sudo virsh net-dumpxml provisioning <network> <name>provisioning</name> <uuid>whatever</uuid> <forward mode='bridge'/> <bridge name='provbr0'/> </network>
Additionally, you want to ensure that the storage pool is big enough, but that is not directly related to the subject at hand.
$ sudo virsh pool-info default Name: default UUID: whatever State: running Persistent: yes Autostart: yes Capacity: 250.92 GiB Allocation: 0 GiB Available: 250.92 GiB
VirtualBMC
The most important part of IPI facilitation is to be able to simulate a baseboard management controller for your VMs. libvirt
obviously doesn't do this, but luckily there's a small bit of Python code that does, and it's called virtualbmc
.
In most Python environments you can install it using pip3
, just make sure pip3
is up-to-date first.
$ pip3 install --upgrade pip ... $ pip3 install virtualbmc ...
This gives you /usr/local/bin/vbmcd
which you can control using the following systemd unit:
[Unit] Description=vbmcd [Service] Type=forking ExecStart=/usr/local/bin/vbmcd [Install] WantedBy=multi-user.target
Put the above content into /etc/systemd/system/vbmcd.service
, reload systemd, and enable/start the service.
$ sudo systemctl daemon-reload $ sudo systemctl enable --now vbmcd
You now have the ability to associate a TCP port with a virtual machine defined on the hypervisor host, and have it simulate an IPMI BMC for that VM!
Virtual Machine Configuration
This section will tie into the #Network Settings section above. You need two bridges on your hypervisor(s), bridge0
and provbr0
.
The virtual machines also need to be configured with sufficient resources, as per #Prerequisites above.
An example control plane node definition in libvirt XML
would look like this:
<domain type='kvm'> <name>controlplane1</name> <memory unit='GiB'>32</memory> <currentMemory unit='GiB'>32</currentMemory> <vcpu placement='static'>12</vcpu> <os> <type arch='x86_64' machine='q35'>hvm</type> <boot dev='hd'/> <boot dev='network'/> <bootmenu enable='yes'/> </os> <features> <acpi/> <apic/> </features> <cpu mode='host-model' check='partial'> <model fallback='allow'/> </cpu> <clock offset='utc'> <timer name='rtc' tickpolicy='catchup'/> <timer name='pit' tickpolicy='delay'/> <timer name='hpet' present='no'/> </clock> <on_poweroff>destroy</on_poweroff> <on_reboot>restart</on_reboot> <on_crash>destroy</on_crash> <pm> <suspend-to-mem enabled='no'/> <suspend-to-disk enabled='no'/> </pm> <devices> <emulator>/usr/libexec/qemu-kvm</emulator> <disk type='file' device='disk'> <driver name='qemu' type='qcow2'/> <source file='/var/lib/libvirt/images/controlplane1-vda.qcow2'/> <target dev='vda' bus='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x04' function='0x0'/> </disk> <controller type='usb' index='0' model='qemu-xhci' ports='15'/> <controller type='pci' index='0' model='pcie-root'/> <interface type='bridge'> <mac address='52:54:00:00:fb:11'/> <source bridge='provbr0'/> <model type='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x03' function='0x0'/> </interface> <interface type='bridge'> <mac address='52:54:00:00:fa:11'/> <source bridge='bridge0'/> <model type='virtio'/> <address type='pci' domain='0x0000' bus='0x00' slot='0x09' function='0x0'/> </interface> <console type='pty'/> <channel type='unix'> <source mode='bind'/> <target type='virtio' name='org.qemu.guest_agent.0'/> </channel> <input type='tablet' bus='usb'/> <input type='mouse' bus='ps2'/> <input type='keyboard' bus='ps2'/> <graphics type='vnc' autoport='yes' listen='0.0.0.0'/> <video> <model type='virtio'/> </video> <memballoon model='virtio'/> <rng model='virtio'> <backend model='random'>/dev/urandom</backend> </rng> </devices> </domain>
A couple of things to note:
- the first network interface is attached to
provbr0
, and its PCI address is lower (0x03), causing it to be the PXE default device - the second network interface is attached to
bridge0
, and its PCI address is higher (0x09), making it the second interface (for public connections) - boot order is set to hard disk first, network second, which means the host will only PXE boot if the disk image is unbootable
- the disk image needs to be 64GiB in size at the minimum, but you can make it larger and/or add more disk images if you intend to use the local storage operator
When configuring other nodes, simply remember to change the node name, disk image name, and MAC addresses to be unique. Adjust hardware resources accordingly for compute nodes.
What is important for OCP IPI to be able to perform the installation properly is to register each virtual machine with vbmcd
and assign it with a port.
$ vbmc add --port=6211 controlplane1 $ vbmc list +-------------------+---------+---------+------+ | Domain name | Status | Address | Port | +-------------------+---------+---------+------+ | controlplane1 | down | :: | 6211 | +-------------------+---------+---------+------+ $ vbmc start controlplane1 $ vbmc list +-------------------+---------+---------+------+ | Domain name | Status | Address | Port | +-------------------+---------+---------+------+ | controlplane1 | running | :: | 6211 | +-------------------+---------+---------+------+ $ sudo ss -aunp | grep 6211 UNCONN 0 0 *:6211 *:* users:(("vbmcd",pid=766290,fd=21))
There is no need to run the vbmc
client as root as it is the daemon that is running as root and can see all the VMs accessible through the qemu:///system
URL.
Of course there are options. For any VM you add, you can specify a custom libvirt URL and credentials if necessary (options --libvirt-uri
, --libvirt-sasl-username
, and --libvirt-sasl-password
), a custom set of IPMI admin credentials (options --username
and --password
, they default to admin
and password
), and a custom IP address to listen on (defaults to all addresses, use option --address
to restrict it).
$ vbmc show controlplane1 +-----------------------+-------------------+ | Property | Value | +-----------------------+-------------------+ | active | True | | address | :: | | domain_name | controlplane1 | | libvirt_sasl_password | *** | | libvirt_sasl_username | None | | libvirt_uri | qemu:///system | | password | *** | | port | 6211 | | status | running | | username | admin | +-----------------------+-------------------+
Once started (which just opens the port) you can test the BMC connection using ipmitool
or similar.
$ ipmitool -I lanplus -H localhost -p 6211 -U admin -P password chassis status System Power : off Power Overload : false Power Interlock : inactive Main Power Fault : false Power Control Fault : false Power Restore Policy : always-off Last Power Event : Chassis Intrusion : inactive Front-Panel Lockout : inactive Drive Fault : false Cooling/Fan Fault : false
That's it! We're ready to install OCP!